FHIR Release 3 (STU) Current Build
This page is part of FHIR STU 3 (v3.0.1) in it's permanent home (it will always be available at this URL). It has been superceded by R4 . For a full list of available versions, see the Directory of published versions .

4.2.12.816 4.3.14.11 Code System http://hl7.org/fhir/adverse-event-causality-assess http://terminology.hl7.org/CodeSystem/adverse-event-causality-assess

Vocabulary Patient Care Work Group   Maturity Level : 1 Informative Draft Use Context : Any

This is a code system defined by the FHIR project.

Summary

Defining URL: http://hl7.org/fhir/adverse-event-causality-assess http://terminology.hl7.org/CodeSystem/adverse-event-causality-assess
Version: 4.1.0
Name: AdverseEventCausalityAssessment
Title: AdverseEventCausalityAssessment
Definition: TODO

Codes for the assessment of whether the entity caused the event.

Committee: Regulated Clinical Research Information Management Patient Care Work Group
OID: 2.16.840.1.113883.4.642.1.816 2.16.840.1.113883.4.642.1.1254 (for OID based terminology systems)
Source Resource XML / JSON

This Code system is used in the following value sets:

TODO Codes for the assessment of whether the entity caused the event.

This code system http://hl7.org/fhir/adverse-event-causality-assess http://terminology.hl7.org/CodeSystem/adverse-event-causality-assess defines the following codes:
Code Display Definition
certain assess1 Certain i) Event or laboratory test abnormality, with plausible time relationship to drug intake; ii) Cannot be explained by disease or other drugs; iii) Response to withdrawal plausible (pharmacologically, pathologically); iv) Event definitive pharmacologically or phenomenologically (i.e. an objective and specific medical disorder or a recognized pharmacological phenomenon); or v) Re-challenge satisfactory, if necessary.
probably-likely assess1 placeholder Probably/Likely i) Event or laboratory test abnormality, with reasonable time relationship to drug intake; ii) Unlikely to be attributed to disease or other drugs; iii) Response to withdrawal clinically reasonable; or iv) Re-challenge not required.
possible Possible i) Event or laboratory test abnormality, with reasonable time relationship to drug intake; ii) Could also be explained by disease or other drugs; or iii) Information on drug withdrawal may be lacking or unclear.
unlikely assess2 Unlikely i) Event or laboratory test abnormality, with a time to drug intake that makes a relationship improbable (but not impossible); or ii) Disease or other drugs provide plausible explanations.
conditional-classified assess2 placeholder Conditional/Classified i) Event or laboratory test abnormality; ii) More data for proper assessment needed; or iii) Additional data under examination.
unassessable-unclassifiable Unassessable/Unclassifiable i) Report suggesting an adverse reaction; ii) Cannot be judged because information is insufficient or contradictory; or iii) Data cannot be supplemented or verified.

 

See the full registry of value sets code systems defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code